TABLE SR-1 OCEAN GATEWAY DESIGN CRITERIA CASCO BAY ISLAND TRANSIT DISTRICT Vessels (5) Ferry Length 65 feet to 125 feet Beam 28 feet to 37 feet Draft 6 feet to 10 feet Queuing Embarkment Queue Area3, 4 15 pcev2 Parking1 Short Term Visitors 15 spaces Employee 30 spaces Year-Round Resident 160 spaces Seasonal 40 spaces Operational Considerations * Passenger/pedestrian safety * Mitigation of passenger/vehicle/freight conflicts * Improve pedestrian flow to Commercial Street * Traffic circulation patterns * Freight handling-cargo, passenger * Additional berth for future ferry * Designated school bus staging area Existing Terminal Facility Needs * Customer friendly entrance * Expanded passenger waiting area * General upgrades-restrooms, finishes * Seamless intermodal connections * Information kiosks at 3 locations * Additional space for snack bar, restrooms, mail boxes, secure short term storage area * Increase freight and maintenance areas by 100% * Provide additional administration and employee areas SCOTIA PRINCE INTERNATIONAL FERRY Vessel (1) Length 470 feet to 575 feet (future) Beam 64 feet to 85 feet (future) Draft 17 feet to 20 feet (future) Queuing Embarkment Queue Area3, 5 220 pcev2 (65,000-100,000sf) Disembarkment Queue Area3, 5 220 pcev2 (56,000 - 80,000sf) Parking1, 6 Short Term Visitor 30 spaces Employee 15 spaces Long Term Passenger 400 spaces US Customs & Immigration 15 spaces Terminal Facility Needs * Accommodate elderly and ADA requirements * Protection from weather, minimal distance between parking and terminal * Consider longitudinal, lateral, and vertical movement of ship relative to passenger loading/unloading * U.S. Customs and Immigrations facilities, security requirements * Restrooms, telephones, and currency exchange facilities * Provide for baggage handling to/from vehicles, to lobby, to ship * Storing and service for fuel, potable water, garage, bulk goods, solid waste * Additional records storage needs, conference room space, increase space for ticketing and reservations by 50%, warehouse storage (bonded and nonbonded areas, cold storage, dry goods), spare parts, and general storage (12-15,000 square feet); total square footage needs approximately 36,000 square feet * Emergency vehicle access * Site security for long term parking * Satellite dish, antennas for communications including radio station communications within 1/2 mile * Appropriate fendering and new transfer bridge CRUISE SHIP OPERATIONS Provide 2-3 Port of Call Berths with flexibility for future home port opportunities Ship Length 250 feet to 1,200 feet Beam 50 feet to 130 feet Draft 15 feet to 30 feet Parking1, 6 Port of Call: Visitor 10 spaces Employee 10 spaces Small Home Port: Visitor 10 spaces Employee 10 spaces Terminal Facility Needs * Consider time and travel for elderly, ADA requirements * Provide weather protection * Lobby for 1,000 people * Intermodal connections * U.S. Customs and Immigration facilities, security requirements * Restrooms, telephones, ticket counter facilities * Baggage handling to/from vehicles, on/off the ship, staging and sorting areas * Storing and service for fuel, potable water, garbage, and goods * Warehousing of dry goods, loading, staging, transfer from terminal to ship (15,000 square feet) * Flexible space to accommodate visitors center and exhibition space, public amenities OTHER REQUIREMENTS Intracoastal Ferry (1) Length 100 feet to 350 feet Beam 30 feet to 65 feet Draft 15 feet to 25 feet Parking1 50 spaces Fire Boats (2) Length 40 feet to 65 feet Beam 15 feet Draft 3 feet to 6 feet Parking1 5 spaces Water Taxis Length 20 feet to 50 feet Beam 8 feet to 15 feet Draft 3 feet to 8 feet 8-10 Tug Boats (8-10) Length 100 feet to 150 feet Beam 25 feet to 40 feet Draft 14 feet to 25 feet Parking1 10 spaces Long Island Rescue Boat, Tall Ships, Military Vessels, Visiting Vessels * Emergency vehicle access to Fire Boat, Long Island Rescue Boat, public landing, commercial landing * Maine Narrow Gauge Railroad/Trail/Recreational open space - Parking1 140 spaces * Short term mooring - public boats, water taxi * Administrative office space needed for City, harbor pilots * Fire Boat staffing quarters, office space, maintenance * Public Facilities Notes: 1 Parking space square footage (sf) assumed to be 325 sf per space 2 pcev - passenger car equivalent vehicle 3 Auto queue space assumed to be 22 feet per pcev and 11 foot wide lanes, commercial and bus queue space assumed to be 60 feet per vehicle and 12 foot wide lanes 4 Commercial and bus queue space for CBITD shared with cruise ship operations and includes space for 10 buses or commercial vehicles 5 Includes queuing space for 10 buses and 6 commercial vehicles 6 Parking spaces can potentially be shared by these facilities